EA-Commercial

Element Air™ Commercial
Air Purification System

Most facilities do not check the air for microorganisms on a daily or monthly basis. Bacteria and mold can continuously breed within the environment and on plants. RGF® developed this air treatment system to provide continuous protection in sensitive air spaces.

Air passes through a REME®/PHI oxidation chamber, which destroys airborne microbes with high intensity UV light rays targeted on a quad-metallic compound. The process develops a highly charged atmosphere of hydroxyl radicals, hydro-peroxides and super oxide ions. This atmosphere oxidizes contaminants in the air with friendly oxidizers. By friendly oxidizers, we mean oxidizers that revert back to oxygen and hydrogen after the oxidation process. No chemical residue or dangerous compounds are emitted from the system. Airborne contaminants in the form of bacteria, mold, and yeast continue to be one of the least addressed issues in most facilities.

Left right Aroow
Scroll
ITEM# VOLTS RECOMMENDED CELL REPLACEMENT MATERIALS PDF
CML-** 100-277 VAC, 50/60 Hz 18,000-25,000 hrs. Stainless steel / Polymers

View PDF

  • Reduces
  • Applications
  • Technical Specs

•Microbials
•Mold
•Bacteria
•Pathogens
•Odors/VOCs

•Greenhouses
•Cultivation Rooms
•Large Harvest Rooms
•Processing Rooms

Left right Aroow
Scroll
ITEM # EACML-**
Volts 100-277 VAC, 50/60 Hz
Recommended Cell Replacement 18,000-25,000 hrs.
Installation In-Line
Material Stainless steel / Polymers
Controls Indicator lights
Warranty 1 year (U.S. only)
 Engineered to fit specific cfm applications in large commercial and industrial environments
 Commercial 20 – Housing is 20″ L   # of cells  Length of cells  CFM Coverage  Tonnage
 EACML-25  1  14″  9,730  25
 EACML-50  2  14″  19,460  50
 EACML-75  3  14″  29,120  75
 EACML-100  4  14″  38,920  100
 Commercial 35 – Housing is 35″ L  # of 35″ cells  # of 14″ cells  CFM Coverage  Tonnage
 EACML-65  1  0  25,020  65
 EACML-90  1  1  34,750  90
 EACML-115  1  2  44,480  115
 EACML-140  1  3  54,210  140
 EACML-125  2  0  50,040  125
 EACML-150  2  1  59,770  150
 EACML-180  2  2  69,500  180
 EACML-190  3  0  75,060  190
 EACML-215  3  1  84,790  215
 EACML-250  4  0  100,080  250
 COMMERCIAL UNITS (EACML)
 CELL REPLACEMENTS
 MODEL NUMBER  14″ CELL  36″ Cell Type 1  36″ Cell Type 2  36″ Cell Type 3
SA-CML-14  SA-CML-0000  SA-CML-0100  SA-CML-2575
 EACML-25  1
 EACML-50  2
 EACML-75  3
 EACML-100  4
 EACML-65  1
  EACML-90  1  1
 EACML-115  2  1
 EACML-140  3  1
 EACML-125  1  1
 EACML-150  1  1  1
  EACML-180  2  1  1
 EACML-190  1  1  1
 EACML-215  1  1  1  1
 EACML-250  2  1  1
14″ CELL = 25,000 cfm’s
36″ CELL = 65,000 cfm’s
 Electrical Data
 Model  Volts  Frequency  Amps  Watts
 EACML-25  80 – 240 VAC  50/60 Hz  0.25  30
 EACML-50  80 – 240 VAC  50/60 Hz  0.55  66
 EACML-75  80 – 240 VAC  50/60 Hz  0.9  108
 EACML-100  80 – 240 VAC  50/60 Hz  1.1  132
 Model  Volts  Frequency  Amps  Watts
 EACML-65  80 – 240 VAC  50/60 Hz  0.6  72
 EACML-90  80 – 240 VAC  50/60 Hz  0.87  104
 EACML-115  80 – 240 VAC  50/60 Hz  1.2  144
 EACML-140  80 – 240 VAC  50/60 Hz  1.6 192
 EACML-125  80 – 240 VAC  50/60 Hz  1.1  132
 EACML-150  80 – 240 VAC  50/60 Hz  1.1  132
 EACML-180  80 – 240 VAC  50/60 Hz  1.8  216
 EACML-190  80 – 240 VAC  50/60 Hz  1.7  204
 EACML-215  80 – 240 VAC  50/60 Hz  2.05  246
 EACML-250  80 – 240 VAC  50/60 Hz  2.15  258

EQmCI0cdTOGrq8Mr7LGpY-Hqln_y8gbnFD9zJFL7Tx8