Element Air™ Commercial
Air Purification System
Most facilities do not check the air for microorganisms on a daily or monthly basis. Bacteria and mold can continuously breed within the environment and on plants. RGF® developed this air treatment system to provide continuous protection in sensitive air spaces.
Air passes through a REME®/PHI oxidation chamber, which destroys airborne microbes with high intensity UV light rays targeted on a quad-metallic compound. The process develops a highly charged atmosphere of hydroxyl radicals, hydro-peroxides and super oxide ions. This atmosphere oxidizes contaminants in the air with friendly oxidizers. By friendly oxidizers, we mean oxidizers that revert back to oxygen and hydrogen after the oxidation process. No chemical residue or dangerous compounds are emitted from the system. Airborne contaminants in the form of bacteria, mold, and yeast continue to be one of the least addressed issues in most facilities.

ITEM# | VOLTS | RECOMMENDED CELL REPLACEMENT | MATERIALS | ||
---|---|---|---|---|---|
CML-** | 100-277 VAC, 50/60 Hz | 18,000-25,000 hrs. | Stainless steel / Polymers |
- Reduces
- Applications
- Technical Specs
•Microbials
•Mold
•Bacteria
•Pathogens
•Odors/VOCs
•Greenhouses
•Cultivation Rooms
•Large Harvest Rooms
•Processing Rooms

ITEM # | EACML-** | |||
Volts | 100-277 VAC, 50/60 Hz | |||
Recommended Cell Replacement | 18,000-25,000 hrs. | |||
Installation | In-Line | |||
Material | Stainless steel / Polymers | |||
Controls | Indicator lights | |||
Warranty | 1 year (U.S. only) | |||
Engineered to fit specific cfm applications in large commercial and industrial environments | ||||
Commercial 20 – Housing is 20″ L | # of cells | Length of cells | CFM Coverage | Tonnage |
EACML-25 | 1 | 14″ | 9,730 | 25 |
EACML-50 | 2 | 14″ | 19,460 | 50 |
EACML-75 | 3 | 14″ | 29,120 | 75 |
EACML-100 | 4 | 14″ | 38,920 | 100 |
Commercial 35 – Housing is 35″ L | # of 35″ cells | # of 14″ cells | CFM Coverage | Tonnage |
EACML-65 | 1 | 0 | 25,020 | 65 |
EACML-90 | 1 | 1 | 34,750 | 90 |
EACML-115 | 1 | 2 | 44,480 | 115 |
EACML-140 | 1 | 3 | 54,210 | 140 |
EACML-125 | 2 | 0 | 50,040 | 125 |
EACML-150 | 2 | 1 | 59,770 | 150 |
EACML-180 | 2 | 2 | 69,500 | 180 |
EACML-190 | 3 | 0 | 75,060 | 190 |
EACML-215 | 3 | 1 | 84,790 | 215 |
EACML-250 | 4 | 0 | 100,080 | 250 |
COMMERCIAL UNITS (EACML) | ||||
CELL REPLACEMENTS | ||||
MODEL NUMBER | 14″ CELL | 36″ Cell Type 1 | 36″ Cell Type 2 | 36″ Cell Type 3 |
SA-CML-14 | SA-CML-0000 | SA-CML-0100 | SA-CML-2575 | |
EACML-25 | 1 | |||
EACML-50 | 2 | |||
EACML-75 | 3 | |||
EACML-100 | 4 | |||
EACML-65 | 1 | |||
EACML-90 | 1 | 1 | ||
EACML-115 | 2 | 1 | ||
EACML-140 | 3 | 1 | ||
EACML-125 | 1 | 1 | ||
EACML-150 | 1 | 1 | 1 | |
EACML-180 | 2 | 1 | 1 | |
EACML-190 | 1 | 1 | 1 | |
EACML-215 | 1 | 1 | 1 | 1 |
EACML-250 | 2 | 1 | 1 | |
14″ CELL = 25,000 cfm’s | ||||
36″ CELL = 65,000 cfm’s | ||||
Electrical Data | ||||
Model | Volts | Frequency | Amps | Watts |
EACML-25 | 80 – 240 VAC | 50/60 Hz | 0.25 | 30 |
EACML-50 | 80 – 240 VAC | 50/60 Hz | 0.55 | 66 |
EACML-75 | 80 – 240 VAC | 50/60 Hz | 0.9 | 108 |
EACML-100 | 80 – 240 VAC | 50/60 Hz | 1.1 | 132 |
Model | Volts | Frequency | Amps | Watts |
EACML-65 | 80 – 240 VAC | 50/60 Hz | 0.6 | 72 |
EACML-90 | 80 – 240 VAC | 50/60 Hz | 0.87 | 104 |
EACML-115 | 80 – 240 VAC | 50/60 Hz | 1.2 | 144 |
EACML-140 | 80 – 240 VAC | 50/60 Hz | 1.6 | 192 |
EACML-125 | 80 – 240 VAC | 50/60 Hz | 1.1 | 132 |
EACML-150 | 80 – 240 VAC | 50/60 Hz | 1.1 | 132 |
EACML-180 | 80 – 240 VAC | 50/60 Hz | 1.8 | 216 |
EACML-190 | 80 – 240 VAC | 50/60 Hz | 1.7 | 204 |
EACML-215 | 80 – 240 VAC | 50/60 Hz | 2.05 | 246 |
EACML-250 | 80 – 240 VAC | 50/60 Hz | 2.15 | 258 |